Dimensions:

Round: Exterior Ø 5 to 165 mm.

 

Alloys

 

Material Designation Composition in % (m/m) Density2 g/cm3 approx.
Symbolic Numerical Element Cu1 P
Cu-DHP CW024A min. 99,90 0,015 8,9
max. – 0,040
1 Including silver up to a maximum of 0.015%
2 Only for information.

 

 

Equivalences

 

EN DIN ASTM AFNOR BS JIS SN
Symbolic Numerical Symbolic Numerical
Cu-ETP CW004A E-Cu58 20065 C11000 CuA1 C101 C1100 Cu-ETP
Cu-OFE CW009A – – C10100 CuC2 C110 – Cu-OFE
Cu-OF CW008A OF-Cu 2.0040 C10200 CuC1 C103 C1020 Cu-OF
Cu-HCP CW021A Se-Cu 2.0070 – – – – –
Cu-PHC CW020A Se-Cu 2.0070 C10300 – – – Cu-HCP
Cu-PHCE CW022A – – – – – – –
CuAg0,10 CW013A CuAg0,10 2.1203 C10700 – – – –
C10940
C11600
CuAg0,04P CW014A – – C11904 – – – –
CuAg0,10P CW016A CuAg0,1P 2.1197 C11907 – – – CuAg0,1P
Cu-DHP CW024A SF-Cu 2.0090 C12200 CuB1 C106 C1220 –
C1221
Cu-DLP CW023A SW-Cu 2.0076 C12000 CuB2 – – Cu-DLP
CuTeP CW118C CuTeP 2.1546 C14500 CuTe 1336 C109 – CuTeP
CuFe2P CW107C CuFe2P 2.1310 C19400 – CW107C – –
Cu-S CW114C CuSP 2.1498 C14700 Cu-S 1336 C111 – Cu-S

 

 

Technical characteristics

 

Designations Wall Thickness
t
mm
Tensile Strength
Rm
N/mm2
min.
Yield Limit at 0.2% Elongation
Rp0.2
N/mm2
Elongation
A
%
Hardness
Material Treatment State Up to and including HB HV
Symbolic Numerical min. max min. min. max. min. max.
Cu-DHP CW024A M 20 – – – – – – – –
R200a 20 200 – 110 40 – – – –
H040a 20 – – – – 40 65 35 60
R250 10 250 150 – 20 – – – –
H070 10 – – – – 70 100 65 95
R290 5 290 250 – 5 – – – –
H095 5 – – – – 95 120 90 115
–
R360 3 360 320 – – – – – –
H110 3 – – – 110 – 105 –
a In annealed state.

 

 

Tolerances

 

Nominal Diameter Tolerances of mean diameter
above up to and inc. applicable to the mean diameter Applicable to any diameter including deviations from the circular shape for straight lengthsa,b
3c 10 ± 0,06 ± 0,12
10 20 ± 0,08 ± 0,16
20 30 ± 0,12 ± 0,24
30 50 ± 0,15 ± 0,30
50 100 ± 0,20 ± 0,50
100 200 ± 0,50 ± 1,00
200 300 ± 0,75 ± 1,50
300 450 ± 1,00 ± 2,00
a The tolerances indicated in this column are not applicable to 

  • tubes in rolls or coils
  • tubes with OD/T>50
  • tubes In an annealed state

b When the diameter is measured at a distance from the ends of the tube of up to 100mm or the equivalent of to a nominal diameter (choosing the lesser of both values), unless otherwise agreed, the tolerance is allowed to be increased by multiplying it by 3.

c Includes 3.

 

Nominal exterior diameter Tolerances of nominal wall thickness t (%)
mm t from 0.3 mm up to and inc. 1 mm t above 1 mm, up to and inc. 3 mm t above 3 mm, up to and inc. 6 mm t above 6 mm, up to and inc. 10 mm t above 10mm
above up to and inc
3a 40 ± 15 ± 13 ± 11 ± 10 –
40 120 ± 15 ± 13 ± 12 ± 11 ± 10
120 250 – ± 13 ± 13 ± 12 ± 11
250 450 – – ± 15 ± 15 ± 15
a Includes 3.

Tolerances of diameter including deviations from circular shape, tubes in rolls or coils

Nominal exterior diameter Tolerances of nominal diameter including deviations from the circular shape Applicable to inner diameter of winding
above up to and inc min.
3a 6 ± 0,30 400
6 10 ± 0,50 600
10 20 ± 0,70 800
20 30 ± 0,90 1000
a Includes 3.

 